Catalogue 9 - STAUFF Filtration Technology

56 www.stauff.com/9/en/#56 C High and Medium Pressure Filters § Type SF / SF-TM / SFZ / SFA The following characteristics are valid for mineral oils with a density of 0,85 kg/dm 3 and the kinematic viscosity of 30 mm 2 /s (30 cSt). The characteristics have been determined in accordance to ISO 3968. Multipass filter ratings have been obtained in accordance to ISO 16889. Contact STAUFF for details. Housing & Valves SF/SFA-014/030 0 60 120 0 7.5 15 22.5 30 43.5 29 14.5 0 ∆p in PSI ∆p in bar Q in l/min Q in US GPM 3.0 2.5 2.0 1.5 1.0 0.5 0 A B D Housing & Valves SF/SFA-045/070/125 0 120 240 0 15 30 45 60 43.5 29 14.5 0 ∆p in PSI ∆p in bar 3.0 2.5 2.0 1.5 1.0 0.5 0 A B D Q in l/min Q in US GPM Valve Configuration Flow direction Curve Housing with HVO/IO or HVB/IB Inlet " Outlet A HVM, HVR, HVN Inlet " Outlet B HVM,HVR Reverse mode Outlet " Inlet D Housing & Valves SF-090/160/250/300 0 250 500 750 1000 1250 72.5 58 43.5 29 14.5 0 ∆p in PSI ∆p in bar Q in l/min Q in US GPM 5.0 4.5 4.0 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0 A B D 0 30 60 90 120 150 180 210 240 270 300 Maximum allowed flowrate HVM, HVR Catalogue 9 § Edition 02/2023 Pressure Filters Note: For high dynamic applications and applications with very high cycle numbers (pressure and volume flow) please contact STAUFF. The service life of HVM, HVR valves may be affected by high flows or fast/frequent load changes. For more information, please contact STAUFF.