Catalogue 8 - STAUFF Diagtronics

72 www.stauff.com/8/en/#72 C Flow Control Valve § LPM-II-DAV Product Description In systems in which the volumetric flow or the pressure is too high, the optimum flow is achieved with the use of a flow control valve. It can process pressures from 4 bar ... 400 bar / 58 PSI ... 5801 PSI. The LPM-II-DAV, flow control valve is connected to the hydraulic outlet of the LPM-II-plus via the connection fittings. Max. Permissible Operating Pressure ƒ 400 bar / 5801 PSI (Note: Note that a minimum operating pressure of 4 bar / 58 PSI must be maintained for the proper function of the flow control valve.) Order Code LPM-II-DAV - M a Series and Type Flow Control Valve LPM-II-DAV b Fluid Compatibility Fluids based on Mineral Oil and Petroleum (standard) M Phosphate Ester (e.g. Skydrol®) E Specific Water Glycols G Diagtronics LPM-II-plus LPM-II-plus with flow control valve LPM-II-DAV M16x2 test coupling SW24 ~145,5 SW19 (5.73) Flowrate ok Flowrate too low Flow control valve required Flowrate too high Viscosity in mm²/s Δp in bar between LPM-II-plus inlet and outlet 100 10 1 0.1 0.01 0,001 1 10 100 1000 Flow Flow Catalogue 8 § Edition 05/2021 Oil Analysis Equipment M M LPM LPM Installation Pressure Line Installation Return Line Flow Flow Application example