Catalogue 8 - STAUFF Diagtronics

www.stauff.com/8/en/#53 B 53 Reader § Type Reader-PT-RF Product Description The hand-held readers transfer the energy required for a measurement to the pressure transmitter using RFID technology. All that is required is a maximum distance of 1.5 cm / 0.6 in from the antenna to the tip of the pressure transmitter for the duration of the measurement. When the pressure transmitter is activated by the press of a button, a current measured value is determined within only 0.5 seconds and then immediately transmitted back to the reading device together with other relevant information and then output on the illuminated display and stored. Over 15,000 of these measurement sets can be stored in the internal memory of the device. PC Software The software included with the delivery allows transmission of the stored measured values from the reading device to the PC, subsequent evaluation and export, e.g. to Microsoft Excel®. Order Code Reader-PT-RF Type of Measurement Start Measurement 1. Switch on the reader using the function button. During the brief start process, the charge state of the lithium ion battery (Battery) is shown on the display and the share of the currently occupied data memory (MemUsed) in percent as well as the current date and time. 2. Position the tip of the antenna of the reader inside the measurement range of the pressure transmitter and hold this position as long as possible during the entire measurement process. a Series and Type Reader Reader-PT-RF Standard option: ƒ Reader-PT-RF ƒ Manual and software on CD ƒ Quick guide ƒ USB 2.0 cable (1 m / 3.28 ft) ƒ 5 V DC / 1 A power supply incl. country-specific adaptors Individual Measurement (Single Value) 3. Start the individual measurement by tapping the function button once. Permanent Measurement (Multiple Values) 3. Start the permanent measurement by holding down the function button . The simplest way of recognising the successful start of a permanent measurement is the change in the corresponding symbol in the upper right-hand corner of the display. The absolute number of the values determined as part of the measurement process is shown below the current pressure. 4. End a continuous measurement by releasing the function key . Display after successful individual measurement Display after successful permanent measurement 1 Serial number 2 Upper full scale 3 Type of measurement 4 Current pressure 5 Measurement ID 6 Current temperature 1 Serial number 2 Upper full scale 3 Type of measurement 4 Last pressure 5 Ø pressure 6 Number of measurements 7 Measurement ID 8 Ø temperature I MIN /MAX pressure 1 2 3 4 5 1 32 7 8 6 Reader-PT-RF Set Up Connection Reader Buttons Display Measurement Range Distance: max. 1.5 cm / 0.6 in within the measurement range indicated Antenna Cap Housing SW24 Hex .95 Pressure Transmitter (direct assembly without adapter) Application Side 6 a 4 5 I Technical Data Material ƒ Housing made of ABS Dimensions / Weight ƒ Dimensions: 76 x 35 x 240 mm / 3.0 x 1.38 x 9.45 in ƒ Weight: 220 g / .49 lbs Measurements / Display ƒ Pressure: in bar and PSI ƒ Temperature: in °C and °F ƒ Display: graphic, LED backlit ƒ Visible area: 55 x 46 mm / 2.17 x 1.81 in ƒ Resolution: 128 x 64 Pixel Power Supply ƒ Battery: Lithium Ion (3,7 V DC / 900 mAh) ƒ Operating time approx. 6h (approx. 1800 individual measurement) Temperature Range ƒ Ambient temp.: -20 °C ... +70 °C / -4 °F ... +158 °F ƒ Storage temp.: -25 °C ... +60 °C / -13 °F ... +140 °F ƒ CE certified Electrical Data / Interface ƒ Sampling rate: typ. 250 ms / max. 400 ms ƒ Interface: Micro USB ƒ EMV: EN 61326-1:2013 EN 300330 Protection Rating ƒ IP65 protection rating: Dust tight and protected against water jets Catalogue 8 § Edition 05/2021 Hydraulic Testers

RkJQdWJsaXNoZXIy ODUyNzU=